Skip to content

Free Support

(501) 255-7760

Secure Vision of America Logo, small size
  • Case Stories
  • Solutions
    • AMI/ALD Meter Solutions
    • AMR Meter Solutions
    • Water Loss Management Software
Menu
  • Case Stories
  • Solutions
    • AMI/ALD Meter Solutions
    • AMR Meter Solutions
    • Water Loss Management Software
Contact Us

AMI/ALD Meter Solutions

Secure Vision Frame 689

Acoustic Leak Detection

Read More

Sustainable Accuracy

Ultrasonic flow measurement guarantees sustainable accuracy and longevity. Ultrasonic flow measurement is based on the transit time method, and all measurements, references, readings, calculations and data communication are controlled by an advanced, specially designed electronic circuit. Thus, the meter includes no moving parts, which makes flowIQ® 2200, 3200, and 4200 less sensitive to wear and tear and impurities in the water.

Construction

The meter is hermetically closed and vacuum-sealed to prevent humidity from reaching the electronics and avoid condensation between the glass and display. The meter is IP68 (submersible) type tested and suitable for installation in meter pits.

Installation

flowIQ® 2200, 3200, and 4200 are easy to install in all operating environments, horizontally as well as vertically, independent of piping and installation conditions. Consumption data can be read visually from the display, using an optical eye, and remotely read, either by 912.5, 915 or 918.5 MHz (AMR) and 450-470 MHz (AMI) band RF signal, built into the meter.

Specific Features

flowIQ® 2200, 3200, and 4200 measure the water and environment temperatures and it includes acoustic leak detection, securing that water loss is discovered quickly. The unique combination of all the flowIQ® 2200, 3200, and 4200 features reduces current operating costs to measure water usage and minimizes unexpected expenses in connection with possible leakage.

Environmentally Friendly

The meter has been approved according to Drinking Water Standards in multiple countries, and it is certified to NSF/ANSI 61. The meter housing and measuring part are made of the high performance thermoplastic material polyphenylene sulfide (PPS) with 40 % fiberglass, which is free from lead and other heavy metals. The environmental report, Carbon Footprint, documents the meter’s high reusability and low environmental impact, including recycling of materials.

Hygiene

To protect the health of the consumers Kamstrup has a hygienic manufacturing process of the water meters. Kamstrup has a highly automated manufacturing process, and only uses materials which are approved for drinking water. Furthermore, the products gets disinfected before dispatch. The hygiene is being controlled by external accredited laboratories and by frequent audits.

Secure Vision flow IQ 2200

flow IQ® 2200

  • Acoustic leakage detection
  • Intelligent alarms
  • Battery lifetime up to 20 years
Type Number Meter Size Start Flow Max Flow for Continuous Operation Lay Length
Internal Radio (RF) Inches GPM (S) GPM (3) Inches
02-K-02-D-1-8A-8UB ⅝” x ½” 0.01 25 7½”
02-K-02-D-1-8B-8UB ⅝” x ¾” 0.01 25 7½”
02-K-02-D-1-8R-8UB ⅝” x ¾” 0.01 25 5.1"
02-K-02-D-1-8C-8UB ¾” 0.015 32 7½” or 9”
02-L-02-D-1-8B-8UB ⅝” x ¾” 0.015 25 7½”
02-L-02-D-1-8N-8UB ¾” 0.025 35 7½”
02-L-02-D-1-8D-8UB 1” 0.04 55 10 ¾”

Note: 02-K-02-D-1-8C-8UB can be ordered with a 1½” extension and washer (installed by the customer) to fit 7½” or 9” lay lengths.

Note: 02-K-02-D-1-8C-8UB can be ordered with a 1½” extension and washer (installed by the customer) to fit 7½” or 9” lay lengths.

Note: Flow specifications only apply at temperatures below 86 °F

At flows between ‘Start flow’ and ’Minimum flow’ measurement occurs, but accuracy is not warranted.

View flow IQ® 2200 Data Sheet
Secure Vision Flow IQ 3200 1

flow IQ® 3200

  • Acoustic leakage detection
  • Intelligent alarms
  • Battery lifetime up to 20 years
Type Number Meter Size Start Flow Max Flow for Continuous Operation Lay Length
Internal Radio (RF) Inches GPM (S) GPM (3) Inches
02-L-01-D-1-8F-8US 1½” 0.06 120 13"
02-L-01-D-1-8H-8US 2" 0.1 160 17"
02-L-01-D-1-8M-8US 2" 0.1 160 15 ¼”
02-L-01-D-1-8K-8US 3" 0.15 350 12"
02-L-01-D-1-8P-8US 4" 0.35 700 14"

Note: 02-K-02-D-1-8C-8UB can be ordered with a 1½” extension and washer (installed by the customer) to fit 7½” or 9” lay lengths.

Note: Flow specifications only apply at temperatures below 86 °F

View flow IQ® 3200 Data Sheet
Secure Vision flow IQ 4200

flow IQ® 4200

  • Ultrasonic measurement
  • Dual band radio
  • Replaceable battery
Type Number Meter Size Start Flow Max Flow for Continuous Operation Lay Length
Internal Radio (RF) Inches GPM (S) GPM (3) Inches
02E-02-G-1-FR-8US 6" 1.4 1400 18"
02E-02-G-1-GA-8US 8" 1.7 2800 20"
02E-02-G-1-GJ-8US 10" 2 4500 17.7"
02E-02-G-1-GS-8US 12" 2.3 5500 19.7"
View flow IQ® 4200 Data Sheet
Secure Vision of America white color logo
Privacy Policy
Terms and Conditions

Copyright © 2023 SecureVision of America. All Rights Reserved. Website by Blackhawk.

Privacy Policy
Terms and Conditions
Secure Vision of America Logo, small size
  • Case Stories
  • Solutions
    • AMI/ALD Meter Solutions
    • AMR Meter Solutions
    • Water Loss Management Software
Contact Us